Illuminate the Future, Empower Lives!

HPRWG2-35(100A) 35KV Drop-out Fuse Manufacturer Direct Sales

Discover the HPRWG2-35(100A) 35KV Drop-out Fuse - a robust outdoor wind-resistant high-voltage fuse designed to safeguard modern power systems. This article explores its key features, technical specifications, application scenarios, installation, maintenance tips, and customization services. Learn how this fuse ensures reliable power protection in diverse environments, from transmission lines to industrial power systems. Delve into its construction, materials, and customizable options, offering tailored solutions for specific needs. Explore the world of power protection with this comprehensive guide to the HPRWG2-35(100A) 35KV Drop-out Fuse.

+86-173 7345 0100

Overview

The HPRWG2-35(100A) outdoor wind-resistant high-voltage drop-out fuse is an essential component in modern power systems, especially suitable for the 35kV voltage level. This fuse not only provides reliable short-circuit and overload protection in power systems but also possesses excellent wind-resistant performance, ensuring stable operation even in harsh outdoor environments.

Product Features

Technical Specifications

Rated Voltage:35kV
Rated Current:100A
Power Frequency Withstand Voltage:86kV (1 minute)
Lightning Impulse Withstand Voltage:185kV (peak)
Ambient Temperature:-40°C to +50°C
Main Material:High-quality Silicone Rubber

Application Scenarios

The HPRWG2-35(100A) outdoor wind-resistant high-voltage drop-out fuse is widely used in various outdoor high-voltage power systems, including but not limited to:

Installation and Maintenance

Installation Notes:

Maintenance Suggestions:

Customization Services

We provide customization services according to customer requirements, including but not limited to:

Conclusion

The HPRWG2-35(100A) 35KV drop-out fuse is a high-performance and reliable power protection device with excellent wind resistance and stable electrical performance. Suitable for various outdoor high-voltage power system protection needs. We offer manufacturer direct sales and welcome you to contact us for customized services to meet your power protection needs.

Other model parameters

Product modelRated voltage

kV
Current rating

A
Rated most
Big break
current
kA
1min worker
Frequency drying resistance
Voltage
(RMS)
kV
1min worker
Frequency humidity resistance
Voltage
(RMS)
  kV
Rated mines
Impact resistance
Subjected to electric voltage
(Peak)
kV
Divide and combine
load
current

A
(H)RW11-10F/100(200)101006.3423075 10
(200)
(H)RW11-12F/100(200)12(200)(12.5)
(H)RW12-10/100(200)10100
(200)
6.3
(12.5)
4530
(38)
105/
(H)RW12-12/100(200)12
(H)RW12-15/100(200)15
(H)PRWG1-10F/100(200)10100
(200)
6.3
(12.5)
42307510
(200)
(H)PRWG1-12F/100(200)12
(H)RW33-12/100(200)12100
(200)
6.3
(12.5)
423075/
(H)RW33-15/100(200)15
(H)RW5-35/100(200)35100
(200)
6.3
(12.5)
9586185/
40.5
(H)RW10-35/100(200)35100
(200)
6.3
(12.5)
9586185/
40.5
(H)PRWG2-35/100(200)35100
(200)
6.3
(12.5)
9586185/
40.5
XS-12/100(200)12100
(200)
6.3
(12.5)
423075/
XS-15/100(200)15
PD-12/100(200)12100
(200)
6.3
(12.5)
423075/
PD-15/100(200)15
(H)RW3-10/100(200)10100
(200)
6.3
(12.5)
423075/
(H)RW3-12/100(200)12
(H)RW4-10/100(200)10100
(200)
6.3
(12.5)
423075/
(H)RW4-12/100(200)12
(H)RW7-10/100(200)10100
(200)
6.3
(12.5)
423075/
(H)RW7-12/100(200)12
(H)RW10-10/100(200)10100
(200)
6.3
(12.5)
423075/
(H)RW10-12/100(200)12
(H)RW10-10F/100(200)10100
(200)
6.3
(12.5)
42307510
(200)
(H)RW10-12F/100(200)12
(H)RW11-10/100(200)10100
(200)
6.3
(12.5)
423075/
(H)RW11-12/100(200)12

Leave Information